Capacity | 1000VA | 2000VA |
Nominal Battery voltage (Vdc) | 12V | 24V |
I/P Voltage (normal mode) | 100-290 VAC ± 10 VAC |
I/P Voltage (UPS mode) | 180-265 VAC ± 10 VAC |
Max. Change Over time | <=20 ms |
Max. Charging Current (NC) | 9A ± 1.5A | 10A ± 1.5A |
Max. Charging Current (HC) | 12A ± 1.5A | 14A ± 1.5A |
Boost Charging Voltage | According to Battery selection |
Float Charging Voltage | 13.7 ± 2 VDC | 27.4 ± 0.4 VDC |
Battery Boost Voltage | 14.5V | 14.2V | 13.8V |
Battery Low Cut | 10.8V | 10.5V | 10.0V |
Output voltage | 220V Nominal |
Output frequency | 50 ± 0.5 Hz. |
Output wave form (at no load) | Controlled wave form |
Batt. Low alarm (VDC)/Protection | According to Battery selection |
Max. Solar charge controller | 50 A |
Solar Charge controller type | PWM |
Max. Panel Voc. | 22V | 24V |
Max. Panel Vmpp. | 19V | 38V |
Other Sine Wave Models | Normal Battery Voltage | Charge Controller Rating | Solar Charging Current |
Solar-A-750VA/12V | 12V | 30A/12V | 30A |
Solar-A-900VA/12V | 12V | 30A/12V | 30A |
Solar-A-1100VA/12V | 12V | 50A/12V | 30A |
Solar-A-1300VA/12V | 12V | 50A/12V | 30A |
Solar-A-1600VA/24V | 24V | 50A/24V | 30A |
Solar-A-2100VA/24V | 24V | 50A/24V | 30A |
Solar-A-2.5KVA/24V | 24V | 50A/24V | 30A |
Solar-A-2.75KVA/48V | 48V | 50A/48V | 30A |
Solar-A-3.75KVA/48V | 48V | 50A/48V | 30A |
Solar-A-5KVA/48V/96V | 48V/96V | 70A/48V- 50A/96V | 30A |
Solar-A-7KVA/96V/120V | 96V/120V | 70A/96V-50A/120V | 30A |
Solar-A-10KVA/120V/180V | 120V/180V | 70A/120V-50A/180V | 30A |
Solar-A-12KVA/180V/192V | 180V/192V | 50A/180V-50A/192V | 30A |
Solar-A-15KVA/240V | 240V | 50A/240V | 30A |
Solar-A-20KVA/360V | 360V | 50A/360V | 30A |